RTA-Multiple Surgeries with Pseudarthrosis Re-surgery and Bone Grafting

RTA-Multiple Surgeries with Pseudarthrosis Re-surgery and Bone Grafting

Pseudarthrosis of mandibular fracture after many surgeries post RTA

This patient ended up with a horrific fracture to his mandible after a RTA(Road Traffic Accident). He has had four surgeries elsewhere in attempts to correct this. Reconstruction plates used did not heal the fracture site. Each surgery had only led to further worsening of his condition. He ended up with shortening of his mandible on the left side with associated numbness of lip. There was a 2-inch gap at the fracture site with nonunion of his mandibular fracture. The wound had a chronic infection with formation of granulation tissue.

This had led to pseudarthrosis and asymmetry of his face. The patient was feeling very frustrated and hopeless with his situation. He could not even eat well because of the malocclusion. Determined to do something about this, he turned to the Internet. He did extensive Internet research for the best maxillofacial surgeon. This led him straight to our hospital for surgical correction.

Patient presents for correction of nonunited fracture

Dr SM Balaji examined the patient and ordered extensive imaging studies. He explained to the patient that he needed bone grafting for his 2-inch mandibular defect. The patient was in agreement with this treatment plan.

Surgical correction of nonunited left mandibular fracture

After adequate general anesthesia, the preexisting lower archbar was first removed. IMF done with stainless steel wires stabilized the jaws in correct anatomical position. A left sided gingivomucoperiosteal flap was then raised. The flap was then reflected to expose the region of the fracture. There was a 2-inch bony gap with complete nonunion of the fracture. Presence of granulation tissue was also noted. The old titanium plate was then unscrewed and removed. This was next replaced with a thinner new titanium plate. Granulation tissue was then removed. A rib graft was then harvested from the thoracic region. Following this, a Valsalva test demonstrated thoracic patency. This incision was next closed with subcuticular sutures.

Stabilization of the fracture segments

The rib graft was then sectioned to fit into the nonunited fracture site with miniplates. Rib graft pieces were then positioned at the nonunion site and screwed in place. Use of miniplates achieved this. This would ensure complete union of the fractured mandibular bone. The flap was then closed with sutures.

Occlusion reestablished for the patient

Occlusion was then checked and found to be perfect. Intermaxillary fixation was then released. The patient expressed his happiness at the results before discharge.He presented the hospital with a glowing handwritten testimonial about his experience here.

Testimonial

Surgery Video


Blowout Fracture – Zygomatic Orbital Complex Surgery with Open Reduction and Fixation of Zygomatic Complex

Blowout Fracture – Zygomatic Orbital Complex Surgery with Open Reduction and Fixation of Zygomatic Complex

This middle aged man met with a road traffic accident with impact to the left side of his face. He had severe pain and swelling on the left side of his face and was rushed to Balaji Dental and Craniofacial Hospital, Teynampet, Chennai by his family after first aid had been administered elsewhere. Dr. S. M. Balaji examined the patient and ordered a CT scan, which showed a comminuted fracture of his left cheekbone (zygoma) and fracture of the floor of the left orbital bone.

The patient was taken to the operating room and the fracture of the zygomatic complex was approached through a vestibular incision placed in the maxillary buccal sulcus on the left side. A flap was raised and the fracture fragments were carefully stabilized and fixed using plates and screws. The fracture of the floor of the left orbit was next accessed through a transconjunctival approach. The herniated fat and orbital contents were elevated and the titanium mesh that had been adapted to the contours of the floor of the orbit was placed over the fracture site to stabilize it. The mesh was then anchored to the orbital margin using screws. The surgical sites were then closed with sutures. The patient recovered from general anesthesia without complications and was taken to his room in stable condition.

Surgery Video